Pressão intra-ocular pós-facectomia: sutura de nylon x poliéster

Pressão intra-ocular pós-facectomia: sutura de nylon x poliéster

Autores:

Paulo Augusto de Arruda Mello,
João Antônio Prata Júnior

ARTIGO ORIGINAL

Arquivos Brasileiros de Oftalmologia

versão impressa ISSN 0004-2749versão On-line ISSN 1678-2925

Arq. Bras. Oftalmol. vol.53 no.6 São Paulo nov./dez. 1990

http://dx.doi.org/10.5935/0004-2749.19900003

SUMMARY

Two groups of twenty patients were studied. Nylon corneal sutures were used in one group and poliester corneal sutures were used in the other, for a purpose of analysing the intra-ocular pressure behavior during the first 24 hours of postoperative period. The statistic study didn't reveal any difference between the two groups.

REFERÊNCIAS

1 RICH, WJCC - Intra-ocular pressure and wound closure after cataract extraction - Trans Ophthalmol Soc U K, 1968(88):437-439.
2 RICH, WJCC - Further studies on early postoperative ocular hypertension following cataract extraction - Trans Ophthalmol Soc U K, 1969 (89):639-645.
3 GALIN, MA; LONG-KUANG LIN, L; OBSTBAUM, SA - Cataract extraction and intraocular pressure. - Trans Ophthalmol Soc U K 1978 (98): 124-127.
4 KRONENTHAL, R; BLAUDER, JE - Sutures marerial in cataract surgery in Cataract and intraocular lens surgery, Vol I, cap.12:122, 1984.
5 RUIZ, RS; WILSON, CA; MUSGROVE, KH; PRAGER, TC - Management of increased intraocular pressure after cataract extraction - Am J Ophthal, 1987 (103):487-491.
6 MELAMED, S - Alteration of trabecular aqueous flow after cataract extraction - Ophthalmic Surg, 1987 (18):878-881.
7 GROSS, JG; MEYER, DR; ROBIN, AL; FILAR, AA; KELLEY, JS - Increased intraocular pressure in the immediate postoperative period after extracapsular cataract extraction - Am J Ophthal, 1988 (105):466-469.
8 WEST, DR; LESCHWE, TD; THOMPSON, LM; IDE, CH - Comparative efficacy of beta-blockers for the prevention of increased intraocular pressure after cataract extraction - Am J Ophthal, 1988 (106): 168-173.
9 MACKENSEN, G - Principles and basic techniques of ocular microsurgery em Clinical Ophthalmology, 1988, vol 5 (4):8.
10 MASKET, S - Comparison of suture materiaIs for closure of the scleral pocket incision - J Cataract Refract Surg, 1988 (14):548-551.
11 DREWS, R C - Astigmatism after cataract surgery: nylon versus mersilene - Ophthalmic Surg, 1989 (20):695-696.
12 CRAVY, TV - Long-term corneal astigmatism relaled to selected elastic, monofilament noabsorbable sutures - J. Cataract Refract Surg, 1989 (15):61-65.