SUMMARY

The use of hydroxyapatite as an ocular implant is a new procedure. This paper demonstrates the surgical experience and clinical results in nine patients after enucleation and evisceration. The results are great. None of them presented infection or extrusion of their implantes and all of them presented great motility and aesthetical appearance.

REFERÊNCIAS

1 DANS, W. - Ancient and Contemporary history of artificial eyes. Advances in anophthalmic socket - vol. 8 - 1990 - p.1 - 10.
2 DUTTON, J. J. - Coraline Hydroxyyapatite as an ocular implant - Ophthalmology - 1991 - 98:370 - 377.
3 MELTZER, M.A., SCOFFER, D. P., ROCCAD. C. D. - Evisceration - Ophthalmic Plastic and Reconstructive Surgery, 1987 - vol. 2 p. 1300.
4 MULLER, T. A., ISHIDA, K. B. S., KOBAYASHI, M., WOLLMAN, J. S., TURK, A. C., HOLMES, R. E., The induction of bone an osteogenic protein and the conduction of bone by porous hydroxyapatite laboratory study in rabbit - Plastic and Reconstructive Surgery. Jan. 1991 p. 87-95.
5 PERRY, A. C. - Integrated orbital implants - Advances in Anophthalmic socket, vol. 8 - 1991- p. 75 - 80.
6 ROSEN, H. M. - Porous block hydroxyapatite as an interpositional bone graft substitute in orthognathic surgery - Plastic and reconstruct. Surg., Jun. 1989 p. 985 - 993.
7 SHAEFFER, D. P., ROCCA, D. C. D. - Enucleation - Ophthalmic Plastic and reconstructive surgery - 1987 - vol. 2 p. 1278 - 1298.
8 SHlELDS, C. L., SHlELDS, J. A., EAGLE, R. C. & POTTER, P. - Histopathologic evidence of fibro-vascular ingrowth four weeks after placement of hydroxyapatite orbital implant. - American Journal of Ophthalmology. March 1991 p. 363-6.